Resources

Technical white papers, product data sheets, and documentation for water quality professionals.

edit_note

Blog

Product launches, technical deep-dives, and water treatment insights from the Halogen engineering team.

mark_email_read

Newsletter

Subscribe for product news, technical updates, and field case studies — delivered to your inbox.

Case Studies

Real-world deployments from utilities across the United States.

View all case studiesarrow_forward
County of Maui Department of Water Supply

Maui, Hawaii

County of Maui Department of Water Supply

Remote groundwater sites with variable pressure — zero calibration since June 2024 installation.

downloadDownload PDF
Orange County Utilities

Orange County, Florida

Orange County Utilities

~2,080 man-hours saved per year across five sensors. Proven across three distinct treatment chemistries.

downloadDownload PDF
Iron Bridge Water Reclamation Facility

Orlando, Florida

Iron Bridge Water Reclamation Facility

Zero calibration over 3-month trial. Old sensors required 3 calibrations per day. EPA 334 approval submitted.

downloadDownload PDF
Palm Beach County Water Utilities

Palm Beach County, Florida

Palm Beach County Water Utilities

2 years, no issues. Only 3 calibrations in 2 years. Replacing full fleet of Hach CL-17 units county-wide.

downloadDownload PDF
City of Lakewood Water Resources

Lakewood, California

City of Lakewood Water Resources

Zero waste stream, NSF-61 certified. Wet-tap caught real-time chlorine dropout that would have gone undetected.

downloadDownload PDF
Compton / Durville Evaluation Report

California

Compton / Durville Evaluation Report

Independent third-party evaluation of MP5 sensor performance documenting real-world accuracy, stability, and operational findings.

downloadDownload PDF

Technical Guidance

Field guides, calibration procedures, and technical notes for operators and engineers.

View all guidesarrow_forward
monitoring

Your Chlorine Sensor Is Lying to You — Here's 65 Days of Proof

A compelling data-driven look at how conventional chlorine sensors drift and misreport over time, with 65 days of side-by-side comparative data.

By Halogen Systems Inc.

Sensor AccuracyData AnalysisCalibration Drift
science

Technical Guidance Note: DPD and Total Chlorine Calibration

Detailed technical guidance on calibrating total chlorine measurements using DPD reference methods. Covers procedure, tips, and common errors. Version 1.2.

By Halogen Systems Inc.

CalibrationTotal ChlorineDPDTechnical Note
menu_book

Simple Guide: DPD and Total Chlorine Calibration

A straightforward field guide for operators performing DPD-based total chlorine calibration. Written for technicians — plain language, step by step. Version 1.0.

By Halogen Systems Inc.

CalibrationField GuideTotal ChlorineOperators
tune

Calibrating Total Chlorine with Free Chlorine

Explains the relationship between total and free chlorine measurements and how to use free chlorine references to calibrate total chlorine sensors accurately.

By Halogen Systems Inc.

CalibrationFree ChlorineTotal ChlorineMethodology
lock_open

Guides & Interactive Tools

Download our buyer's guide, ROI calculator, technical reference, technology selector, and comprehensive chlorine analyzer guide — free with registration.

Published Articles

Featured in WaterOnline, AWWA Opflow, and other industry publications.

View all articlesarrow_forward
article

Investigating Chlorine Monitoring Options for Water Conservation and Safety

How the City of Lakewood, CA solved its water waste and infrastructure challenges with a new in-pipe chlorine sensor. Published in AWWA Opflow, April 2025.

By Michael Santillan, Derwin Dy, Derek Nguyen & Michael Silveri

AWWA Opflow — April 2025

Case StudyLakewood CAWater Conservation
article

Less Waste, Easier Maintenance — Why You Need to Look at Amperometric Sensors

A comprehensive comparison of amperometric sensor technologies including membrane, bare electrode, and direct-insertion designs. Covers NSF-61 certification, flow independence, and self-cleaning systems.

By Michael Silveri

Water Environment Technology — March 2022

TechnologyAmperometricSensor Comparison
article

Streams of Information — A Breakthrough Sensor for Ballast Water Treatment

How Halogen Systems developed cutting-edge TRO sensor technology through a Navy SBIR program, leading to commercial deployment on 1,200+ ships worldwide.

By Office of Naval Research

ONR SBIR Success Story

MaritimeNavy SBIRBallast Water
article

Florida Utility Saves 2,080 Man-Hours With Just 5 Sensors

How a major Florida utility dramatically reduced labor costs and improved water quality monitoring by deploying five Halogen MP5 sensors across their distribution system.

By Halogen Systems

WaterOnline — March 2026

Case StudyLabor SavingsDistribution
article

Your Chlorine Sensor Is Lying to You — Here's 65 Days of Proof

A data-driven investigation showing how conventional chlorine sensors drift and misreport over time, with 65 days of side-by-side comparative data proving the accuracy gap.

By Halogen Systems

WaterOnline — March 2026

Sensor AccuracyData AnalysisCalibration Drift
article

Water Quality Data Now Available Through SENSUS AMI Systems From Anywhere

How Halogen Systems integrates with Sensus (Xylem) AMI infrastructure to deliver real-time water quality data alongside meter reads — accessible from anywhere.

By Halogen Systems

WaterOnline — November 2025

AMI IntegrationSensusRemote Monitoring
article

Office Of Naval Research Contract Leads To New Chlorine Sensor Technology

The story behind Halogen Systems' origin — how a Navy SBIR contract to solve ballast water treatment led to breakthrough amperometric sensor technology now used in municipal water systems.

By Halogen Systems

WaterOnline — November 2025

Navy SBIRInnovationCompany History
article

Eliminating Chlorine Sensor Pain Points With New Technology

A look at the common frustrations water operators face with traditional chlorine sensors — reagent costs, constant calibration, waste streams — and how new amperometric technology eliminates them.

By Halogen Systems

WaterOnline — November 2025

TechnologyPain PointsMaintenance
article

Sensors Are The Missing Link For Legionella Control In Buildings And Hospitals

Why continuous chlorine monitoring is the critical missing piece in Legionella prevention programs for large buildings, hospitals, and hot water systems.

By Halogen Systems

WaterOnline — November 2025

LegionellaHot WaterBuilding Safety
article

9 Reasons Why Drinking Water Distribution System Monitoring Is Now Practical

Nine technological and economic factors that have made continuous chlorine monitoring throughout the distribution system practical and affordable for utilities of all sizes.

By Halogen Systems

WaterOnline — October 2025

DistributionMonitoringPractical Guide
article

Demand Based Flushing Using AMI And Water Quality Sensors

How integrating water quality sensors with AMI systems enables utilities to replace calendar-based flushing with data-driven, demand-based programs that save millions of gallons.

By Halogen Systems

WaterOnline — September 2025

AMI IntegrationFlushingWater Conservation
article

Chlorine Sensors Waste An Estimated 6.1 Billion Gallons Of Non-Revenue Water Every Year

The hidden cost of traditional chlorine analyzers: their required waste streams add up to 6.1 billion gallons of non-revenue water annually across the U.S. — and how in-pipe sensors eliminate it entirely.

By Halogen Systems

WaterOnline — July 2025

Non-Revenue WaterCost SavingsSustainability

White Papers & Technical Reports

Technical research and application guides from our engineering team.

description

Water Quality Monitoring for Legionella Control

How new sensor technology makes it practical to monitor water quality throughout a building's hot water system for Legionella prevention.

By David J. Swiderski (HC Info) & Michael Silveri (Halogen Systems)

LegionellaHot WaterASHRAE 188
description

Measuring Monochloramine Without Reagents

A new control method for chloramination using the MP-TOTAL sensor to measure free chlorine and monochloramine simultaneously without reagents.

By Halogen Systems Inc.

MonochloramineChloraminationMP-TOTAL
description

MP5-A: A New Standard in Accuracy

Testing shows the MP5-A maintains ±4% accuracy across wide ranges of pH (6.5–8.5), temperature (10–35°C), and conductivity (156–10,000 µS) — outperforming competing sensors.

By Halogen Systems Inc.

AccuracyMP5pH Compensation
description

Demand-Based Flushing with AMI & Water Quality Sensors

How the City of Gainesville, GA uses Halogen sensors integrated with Sensus AMI to optimize flushing operations and reduce non-revenue water.

By Halogen Systems Inc. & Sensus (Xylem)

AMI IntegrationDistributionFlushing
description

Chlorine Analyzers Waste 6.1 Billion Gallons of Non-Revenue Water

Traditional sensors require a 70,000-gallon waste stream per year. The MP5 eliminates this entirely with direct in-pipe installation.

By Halogen Systems Inc.

Water ConservationNon-Revenue WaterCost Savings
description

ORP versus Amperometry for Chlorine Measurement

A technical comparison of ORP and amperometric methods for TRO measurement. Covers electrode poisoning, ±30% ORP error, logarithmic response limitations, and why amperometry is the correct choice for quantitative control.

By Halogen Systems Inc.

ORPAmperometrySensor Technology
description

New Alternatives to Online DPD Instruments for TRO Measurement in BWMS

ACT-evaluated amperometric TRO sensor technology for ballast water management systems. Reagent-free, flow-independent, and DNV Type Approved.

By Halogen Systems Inc.

TROMaritimeSensor Technology

Product Data Sheets

Brochures

Product overviews and quick-reference guides for drinking water and maritime applications.

menu_book

Drinking Water Brochure

8-page overview of MP5-A features, installation options, specifications, and customer testimonials.

menu_book

Operator Brochure

Quick-reference guide covering features, benefits, NSF-61 certification, and the no-maintenance advantage.

directions_boat

Ballast Water TRO Brochure

Maritime TRO sensor models, IECEx certifications, installation diagrams, and SensiCLENE technology.

Product Manuals & Guides

Installation guides, product manuals, and quick start references for all Halogen products.

settings
D20 + MP5A

D20 + MP5A Product Guide

Complete product guide for the D20 Controller Module paired with the MP5A free chlorine sensor.

settings
D20 + MP-Total

D20 + MP-Total Product Guide

Complete product guide for the D20 Controller Module paired with the MP-Total chlorine sensor.

settings
D20 + MP3

D20 + MP3 Product Guide

Complete product guide for the D20 Controller Module paired with the MP3 sensor.

bluetooth
BTSB + MP5A

Bluetooth SmartBox + MP5A Product Guide

Product guide for the Bluetooth SmartBox (BTSB) paired with the MP5A free chlorine sensor.

bluetooth
BTSB + MP-Total

Bluetooth SmartBox + MP-Total Product Guide

Product guide for the Bluetooth SmartBox (BTSB) paired with the MP-Total chlorine sensor.

bluetooth
BTSB + MP3

Bluetooth SmartBox + MP3 Product Guide

Product guide for the Bluetooth SmartBox (BTSB) paired with the MP3 sensor.

battery_full
BTSB-C + MP-Total

Battery-Operated BTSB-C + MP-Total Product Guide

Product guide for the battery-operated Bluetooth SmartBox (BTSB-C) paired with the MP-Total sensor.

build
MP5A

MP5A Operation & Maintenance Guide

Comprehensive operation and maintenance guide for the MP5A sensor. Covers setup, calibration, troubleshooting, and replacement parts.

plumbing
Wet Tap

Wet Tap Sensor Installation Manual

Installation manual for the wet tap direct-insertion sensor. Covers vertical and horizontal installation, component labels, and replacement parts.

rocket_launch
MP6

MP6 Quick Start Guide

Quick start guide for mounting, connecting, and commissioning the MP6 sensor with the MKIT panel.

Need something specific?

Our engineering team can provide custom technical documentation, application notes, and integration guides for your specific deployment.

Contact Engineering